Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0524-03053
Parcel: 11107147D

Address:
2752 N EDITH BL

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0524-03053
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/15/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/15/2024 Site Engineering PENDING ASSIGNMENT
08/15/2024 Site Zoning PENDING ASSIGNMENT
07/23/2024 Residential Building REQUIRES RESUBMIT TC-RES-0524-03053
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans.

Provide a response letter on separate file with the updated construction plan set.

GENERAL COMMENTS :

Place the model plan number on the permit application and description for the correct in-processing of the permit.

This permit request was started as a custom layout plan and requires a complete construction plan submittal, or void this application and start a new application with model number in the description.

SITE PLAN:

1. Show the location of the proposed electrical service (or sub panel feeder), R106.1.1. Each dwelling requires an appropriate source of electrical and water supply, R106.1.1.

PLUMBING PLANS:

1. Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate yard pipe and water meter size.

ELECTRICAL PLANS:

1. TEP may require the service panel for the property at the closest building to the service transformer. A service line change or a new meter location must be coordinated with TEP for approval. Show an underground feeder from a metered service panel to the more distant dwelling.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
07/18/2024 PDSD Application Completeness Express REVIEW COMPLETED