Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0524-02988
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/18/2024 | Site Engineering | NOT REQUIRED | |||
| 06/18/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/29/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0524-02988 (16 E VALESKA RD TUCSON, AZ 85706) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Show the rafter size and spacing on the roof framing for verifying the load carrying capacity, R301.1, R802.4.1. 2. Indicate all materials used for the roofing system, siding, veneer, flashing, water proof membrane, roof covering, etc., R301.1. 3. Show the location of each post and post footing. Include the span measurement for the beam between each post. Locate and size reinforced footings for supporting live and dead structural loads, R401.2. 4. Show exterior footings at least 12” below the undisturbed ground surface, R403.1.4. 5. Show a beam size with appropriate load carrying capacity, R301.1. 6. Limit cantilevered rafters (overhang) to 24”, or provide engineered design, R802.7.1.1. 7. Show ledger to wall connections consistent with Figure R606.11 (1). Change ledger bolt size and spacing for a prescriptive design or provide an or provide an engineer’s sealed plan set for performance compliance consideration, R301.1.3. 8. Show appropriate rafter hangers for the rafter-to-ledger connection, not an H2.5. 9. Does this permit also include a masonry wall? If so provide complete building details for the wall. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 06/05/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0524-02988 16 East Valeska Street – R-2 Porch (1st Review) TRANSMITTAL DATE: June 5, 2024 1. Provide a site plan that meets the residential plot plan requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. The requirements are provided in both graphic and written formats. 2. Setbacks are based on a measurement from the design grade elevation (the ground) to the highest point of the post supporting the roof of the porch (see UDC 6.4.5.B and Figure 6.4.5-A). Provide a dimension on the section drawing to determine the setback requirements. Per UDC Table 6.3-2.A, the required side setbacks are six feet or 2/3 the height of the post supporting the roof of the porch, whichever is greater, measured from the east and west lot lines. Per UDC 6.4.5.C.1.a, the required front street setback is 20 feet as measured from the street property line. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 05/21/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |