Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0524-02852
Parcel: 125050820

Address:
2409 E 5TH ST

Review Status: Requires Resubmit

Review Details: RESTAMP - RESIDENTIAL v.1

Permit Number - TC-RES-0524-02852
Review Name: RESTAMP - RESIDENTIAL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/21/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/21/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0524-02852
2409 E. 5th St. – R-1
Residential addition (2nd Review)

TRANSMITTAL DATE: January 21, 2025

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9

1. This comment was not addressed. The street frontage listed, “GREATER OF 20’-0” OR 1-1/2 HEIGHT” is not correct. Review UDC Article 6.4.5.C.1.a, and correct the front street perimeter yard setback.

2. This comment was not addressed. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” = 20’.

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall, top of parapet, UDC Article 6.4.5.B & Figure 6.4.5-A. As wall height dimensions to the top of parapet, where the parapet steps down Zoning has used the dimension of 23’-8” that was provided to the top of parapet at its highest point to determine required perimeter yard setbacks.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).
1 Based on a wall height of 24’-0” the required interior perimeter yard setback from the proposed 2-story addition to the north, east and west property line is 16’-0”, proposed setback to the north property line is 13’-8”, east property line is 7’-4”, west property line is 8’-9”.

2 Based on a wall height of 13’-2” the required perimeter yard setback from the north wall of the proposed 1-story garage addition to the north property line is 8’-9”, propose setback from the 1-story garage addition is 4’-2”.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.