Review Date Reviewer's Name Type of Review Description Status Comments
05/09/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/09/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0524-02847 (2022 E MONTE VISTA DR TUCSON, AZ 85719)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. Size the pipe based on the length from the meter to the farthest attached appliance on the branch and max total Branch demand of all attached appliances on the branch using Table G2413.4(1) (Metallic Pipe), Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1.
2. For the given lengths and demands, the main 3/4” gas line, to the furnace and water heater, is undersized. Provide sizes in compliance with G2413.4.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov