Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0524-02829
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2024 | Residential Building | APPROVED | |||
| 07/09/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/09/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: TC-RES-0524-02829 126 W ALTURAS ST., TUCSON, AZ 85705 Extend bedroom suite and dining room (1st Review) TRANSMITTAL DATE: 7/9/2024 DUE DATE: 7/14/2024 Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. This site is located in the O-3 zone (UDC 4.7.16). A single-family residence is a permitted use in this zone (Table 4.8-3) subject to Use Specific Standards 4.9.7.B.5 - .9. 1. Comment: The proposed relocation of the second shed does not meet the minimum rear yard setback. Please relocate the shed 10’ from the property line or have the owner setback waiver signed by the “adjacent property owners”. Please see example below for the setback waiver language. Example of an adjacent property owner’s setback waiver for detached accessory structures. The adjacent owner’s waiver statement must be added to the site plan. My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ 2. Comment: The minimum side yard setback is the greater of 10’ or ¾ height of the proposed building wall for the O-3 zone. A Design Development Option (DDO) application review and approval will be required since the proposed addition will require a reduced setback from the East and West property lines. Here is a link to the DDO application: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for _setback_and_height_udc.pdf . 3. Comment: Please update the address on the plans to 128 W. Alturas Street. All sheets on the plans refer to the addition taking place at 126 W. Alturas Street. 4. Comment: Please add the following density calculations per the sample site plan to your plan set: Lot Area = 6,000 sf, .13 acres, 3 units allowed on parcel and 2 existing. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 06/12/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |