Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0524-02829
Parcel: 107141590

Address:
128 W ALTURAS ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.5

Permit Number - TC-RES-0524-02829
Review Name: RESIDENTIAL NEW DWELLING v.5
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/01/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/12/2024 Residential Building REQUIRES RESUBMIT TC-RES-0524-02829 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a response letter on separate file with submitting the updated construction plan set.

Submit the revised construction plan set and support documents in separate PDF files.

Provide a revised application showing the same address in the description as shown on the plans. 128 W Alturas St.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-30 when extended over the wall top plate for additions under 500 SF. Show spray foam or a layer of rigid foam board with a layer of batt at Detail #3 & 4 sheet 3.

MECHANICAL PLANS:

1. Show bathroom (without a window) exhaust fan locations with minimum 50 CFM rating and duct to the exterior, R303.3 and M1505. Add a new exhaust fan for the existing bathroom if not existing.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
10/01/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
PDSD Zoning Review Section

PROJECT: TC-RES-0524-02829
126 W ALTURAS ST., TUCSON, AZ 85705
Extend bedroom suite and dining room (3rd Review)

TRANSMITTAL DATE: 10/1/2024

DUE DATE: 10/9/2024

Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

This site is located in the O-3 zone (UDC 4.7.16). A single-family residence is a permitted use in this zone (Table 4.8-3) subject to Use Specific Standards 4.9.7.B.5 - .9.

1. Comment: Zoning acknowledges a DDO has been applied for and is currently under review. Zoning cannot approve this permit until the DDO has been approved. Please resubmit all documents once the DDO has been approved.

If you have any questions about this transmittal, please contact Bobby Parsons at (520) 837-4977 Robert.Parsons@tucsonaz.gov.
10/01/2024 Zoning Modifications - DDO REQUIRES RESUBMIT FROM: Georgia Pennington, Planner
DATE: 10/1/24

COMMENTS:

1. The submitted DDO application has been deemed complete by staff. If the DDO is approved, provide a copy of your DDO decision letter in addition to a revised plan set and a comment response letter.

Please contact me at Georgia.Pennington@tucsonaz.gov or at 520-837-6311 should you have questions about this transmittal.
09/09/2024 PDSD Application Completeness Express REVIEW COMPLETED