Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0524-02774
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/08/2024 | Fire New Construction | NOT REQUIRED | |||
| 06/04/2024 | Site Engineering | NOT REQUIRED | |||
| 06/04/2024 | Site Landscape | NOT REQUIRED | |||
| 06/04/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/20/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0524-02774 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with submitting the updated construction plan set. STRUCTURAL PLANS: 1. Provide a complete plan set showing materials and fastener sizes with 2018 IRC prescriptive compliance or provide an Arizona professional stamped plan set showing performance compliance with wind loading conditions, R301.1. Show the existing carport beam sized with appropriate capacity for accepting the additional dead loads of enclosing with insulation and ceiling. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-30 when extended over the wall top plate for additions under 500 SF. ELECTRICAL PLANS: 1. Panelboards and overcurrent protection devices shall not be in clothes closets or bathrooms, E3405.5. Relocate panel B. 2. Show receptacle outlets at each kitchen counter space with no point along the wall line more than 24” from a receptacle outlet, E3901.4.1. Show receptacles within 2’ of counter edges or corners and no more than 4’ apart. INTERNATIONAL ENERGY CONSERVATION CODE: Provide insulation details minimum (R-13 walls and R-30 small additions or otherwise R-38 ceiling) showing code compliant placement of materials and ratings, N1101. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 06/03/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0524-02774 3202 E KLEINDALE RD. – R-2 Renovate SFR and Enclose Carport into Bedroom Suite (1st Review) TRANSMITTAL DATE: June 3, 2024 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. 2. The setback shown along Howard Ave. is not correct. Review UDC Article 6.4.5.C.1.b and provide the correct side street perimeter yard setback. 3. The zoning listed under ‘CODE TABULATIONS” is not correct and should be R-2. 4. Label the zoning for all adjacent parcels. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/07/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |