Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-0524-02695
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/28/2024 | Fire New Construction | NOT REQUIRED | |||
06/24/2024 | Site Engineering | NOT REQUIRED | |||
06/24/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/12/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0524-02695 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with submitting the updated construction plan set. Consider using a design professional if unfamiliar with construction documentation. The construction plan set should show all proposed additions, repairs and alterations to the building and utilities. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed. Provide a construction plan set with a page number on each sheet. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: Provide a site plan showing utilities for the dwelling, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. FLOOR PLAN: Provide a floor plan showing each proposed room with labeled function and dimensions. Show door locations and window sizes with type identified as XO or SH. Include the identification of adjacent rooms with door or window openings leading into the proposed space. An altered bedroom requires code compliance for egress, R310. SECTIONS - DETAILS: 1. Provide a structure section showing existing and proposed features including a foundation, framing, sills, anchoring, sheathing and insulation, R106.1. 2. Provide a complete cross-section detail showing type and size of framing, exterior wood siding, insulation, interior sheathing, and pressure treated sill anchored with ½” x 10” bolts with continuous 12” wide by 12” deep reinforced foundation. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. 3. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. MECHANICAL PLANS: 1. Show any proposed changes, R301.1. 2. Show heating/cooling facilities in all habitable rooms, R303.9. ELECTRICAL PLANS: 1. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity, R314.3. 2. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. 3. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3. 4. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. INTERNATIONAL ENERGY CONSERVATION CODE: Provide insulation details minimum (R-13 walls and R-30 small additions or otherwise R-38 ceiling) showing code compliant placement of materials and ratings, N1101. Windows require a solar heat gain of 0.25 or better. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
06/19/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0524-02695 2310 W HELTON LN Unit: 1– MH-1 Enclose Porch into Bedroom (1st Review) TRANSMITTAL DATE: June 19, 2024 Resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the MH-1 zone (UDC 4.7.10). A Mobile Home Dwelling a permitted use in this zone (Table 4.8-2). 1. Provide a residential plot plan that is readable and meets all requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
05/28/2024 | PDSD Application Completeness | REVIEW COMPLETED |