Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.5
Permit Number - TC-RES-0524-02687
Review Name: RESIDENTIAL NEW DWELLING v.5
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/13/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/13/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0524-02687 9226 E 42ND ST . – R-1 Carport Addition (4th Review) TRANSMITTAL DATE: June 13, 2025 Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. A complete a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, shall be provided, to include but not limited to: a. The plot plan shall be drawn at an engineering scale, i.e. 1”=10’, 1” = 20’. b. Provide a lot coverage calculation. c. The dimension from the center line of 42nd St to the north property line is not correct and should be 25’. The dimension from face of curb to the north property line is not correct and should be 10’. Reference Construction Plan I-73-003 sheet 7 found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-73-003. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). 1. Per UDC Table 6.3-2.A, The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line. Based on a wall height of less than 9’-0” the required perimeter yard setback from the proposed carport to the west property line is 6’-0”, proposed setback is 3’-0”. 2. Per UDC Article 6.4.5.C.1.a, the minimum perimeter yard setback to the front street property line is twenty (20) feet, proposed front street perimeter 17’-9”. The DDO must be approved prior to approval of this pemit. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/12/2025 | Zoning Modifications - DDO | REQUIRES RESUBMIT | FROM: Georgia Pennington, Lead Planner COMMENTS: 1. The submitted DDO application has been deemed complete by staff. If the DDO is approved, provide a copy of your DDO decision letter in addition to a revised plan set and a comment response letter. Please contact me at Georgia.Pennington@tucsonaz.gov or at 520-837-6311 should you have questions about this transmittal. |
||
| 05/28/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |