Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0523-05585
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/28/2023 | Site Engineering | NOT REQUIRED | |||
| 07/06/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/06/2023 | Residential Building | REQUIRES RESUBMIT | Provide a complete construction plan set for review after DDO approval. | ||
| 06/29/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0523-05585 1016 S. Fremont Ave. – R-2 New SFR (2nd Review) TRANSMITTAL DATE: June 29, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. As the dimensions on the elevations are from “GROUND FLOOR LEVEL” Zoning will add an additional 6” to all dimensions provided on the elevations to determine perimeter yard setback requirements. 1. Based on a wall height of 20’-0” the required perimeter yard setback from the proposed 2 story portion of the SFR to the south property line is 13’-4”, proposed setback is 3’-4”. 2. Based on a wall height of 11’-8” the required perimeter yard setback from the proposed 1 story portion of the SFR to the south property line is 7’-9”, proposed setback is 3’-4”. 3. Based on a wall height of 10’-8” the required perimeter yard setback from the proposed detached garage to the south property line is 7’-2”, proposed setback is 3’-4”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 06/27/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |