Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0523-05501
Parcel: 141111860

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-RES-0523-05501
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/05/2023 Site Zoning APPROVED
06/05/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
06/02/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0523-05501 (7687 S LIONS SPRING WY TUCSON, AZ 85747)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. Show Spa feeder conductor and conduit sizes with appropriate correction factors, E3705.
2. Use Table E3705.1, 60 degree C column, for sizing branch circuits and conductors rated at 100 AMP or less, E3705.4.1.
3. Show the Spa conductor size and over-current protection (breaker size), E3705.5.
4. Show weatherproof covers at electrical boxes in damp or wet locations, E3905.11.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov