06/05/2023 | Site Zoning | APPROVED | |||
06/05/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/02/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0523-05501 (7687 S LIONS SPRING WY TUCSON, AZ 85747) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Show Spa feeder conductor and conduit sizes with appropriate correction factors, E3705. 2. Use Table E3705.1, 60 degree C column, for sizing branch circuits and conductors rated at 100 AMP or less, E3705.4.1. 3. Show the Spa conductor size and over-current protection (breaker size), E3705.5. 4. Show weatherproof covers at electrical boxes in damp or wet locations, E3905.11. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
05/30/2023 | PDSD Application Completeness | REVIEW COMPLETED |