| 06/26/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/26/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0523-05485 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Provide a complete construction plan set showing 2018 IRC compliance, R106.1. Clarify if the structure is a sleeping quarters (without kitchen) or an Accessory Dwelling Unit (ADU) which requires many alterations for compliance. An independent dwelling (ADU) requires fire spread and utility (electrical & water) separation so that one dwelling is not dependent upon another for water or electrical service. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. An impact fee payment is required for an ADU at time of permit payment. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Each dwelling requires an independent electrical service and water supply shut off devices. Identify the utility lines requiring upgrade or replacement. 2. Show a street address for each dwelling on the site plan, R319. PLANS: 1. Notate a cool (white) roof finish as required by the ADU provisions. 2. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. SECTIONS - DETAILS: 1. Provide concrete foundations for anchoring exterior framed wall sills with ½” anchor bolts with 7” embedment, R403.1.6 and with 6” minimum height above finished grade, R404.1.6. 2. Show an unvented roof assembly with all insulation at the roof including an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing as part of the total insulation requirement, R806.5 or show the attic vent opening size using 1 to 150 of attic area with insulation at the ceiling in compliance with R806.2. PLUMBING PLANS: 1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe for supporting the existing and proposed dwellings and show an appropriate water meter size. 2. Show an individual accessible water supply shut off and water heater for the proposed dwelling unit, P2903.9.1. 3. Provide a complete plumbing plan. MECHANICAL PLANS: 1. Show the HVAC system size for the building demand in accordance with M1401.3, M1601.1. 2. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation, or controlled exhaust with a calculated airflow rate, R303.4; N1103.6 & M1505.4. Show the system and appropriate flow rate setting on the plans. A one bedroom dwelling under 1501 SF requires a 30 CFM continuous setting. 3. Provide a complete mechanical plan. ELECTRICAL PLANS: 1. TEP may require the service panel for the property at the closest building to the service transformer. A service line change or a new meter location must be coordinated with TEP for approval. Show an underground feeder from a metered service panel to the more distant dwelling. 2. Provide a complete electrical plan. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 06/08/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0523-05485 2163 S. Avenida Planeta – R-1 Free-standing shed to tiny home conversion (1st Review) TRANSMITTAL DATE: June 08, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A two dwelling units are a permitted use in the zone, (Table 4.8-2), subject to Use Specific Standards 4.9.7.B.5 -.9. 1. Clarify what you are proposing, the description states “Free-standing shed to tiny home conversion” and the plot plan shows “Guest House”. Are you proposing a 2nd dwelling unit or an Accessory Dwelling Unit (ADU). 2. The provided plot plan cuts of information. 3. The property dimensions shown on the plot plan are incorrect. Review the Assessor’s Record Map found at: https://www.asr.pima.gov/ParcelData/Map/Arm/MP13/M13016_B49B.PDF, and provide the correct dimensions. 4. Provide the legal description, “TERRA DEL SOL LOT 14 BLK 49” on the plot plan 5. Provide perimeter yard setback dimensions from the proposed tiny home to the south & west property lines. 6. Provide a full floor plan for the existing dwelling with your next submittal. 7. Full building plans will be required for the tiny home conversion. 8. Depending on how comment 1 is addressed and the floor plan for the tiny home impact fees may apply. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 06/21/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 05/31/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 06/01/2023 | Site Engineering | REVIEW COMPLETED |