Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0523-05421
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/08/2023 | Site Engineering | NOT REQUIRED | |||
| 06/29/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/29/2023 | Residential Building | REQUIRES RESUBMIT | PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Provide a clear and concise construction plan set. Sample drawings are shown as an example: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Indicate the location electrical lines and service panel, R106.1.1. Show the utility lines requiring relocation or replacement. STRUCTURAL PLANS: 1. Show the location of each support footing, R106.1.1. 2. Provide a Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804. SECTIONS - DETAILS: 1 Show reinforced footing dimensions required for post/beam construction, R403.1.1. 2 Show a complete cross-section detail with post to foundation fasteners, R407.3 & R507.4.1. 3 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 06/13/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-RES-0523-05421 8335 S VIA DE ELLSWORTH Zoning R-2 TRANSMITTAL DATE:‎June 13, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf This shall in include: a. Lot coverage calculation that meets the requirements of UDC Article 6.4.3 & the example shown on the residential plot requirements. (Lot coverage must include vehicular use area whether improved or unimproved) . Lot coverage does not include porches, UDC Article 6.4.3.C.1.a but does include vehicle use area measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved. b. Zoning of adjacent parcels c. All Utility lines d. Property line distances In the link provided below is a Plot plan grid that can be used. https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Grid.pdf 2.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 06/08/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |