Permit Number - TC-RES-0523-05312
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/05/2023 | Site Zoning | APPROVED | |||
| 06/20/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/20/2023 | Residential Building | REQUIRES RESUBMIT | 1. Show the functional name of each proposed room and each adjacent room, R106.1.1. Existing bedrooms with removed windows must show code compliance for egress, R310. 2. Framed exterior walls of enclosed roof structures require continuous reinforced concrete footings of minimum 12” width and 12” below the undisturbed ground surface, R403.1. Locate and specify all anchor-bolt spacing on the foundation plan. Minimum ½” diameter with (anchor bolt length for assuring) 7” embedment into concrete or masonry, R403.1.6. Update detail #5/S1.0. 3. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3. |
||
| 05/22/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 05/23/2023 | Site Engineering | REVIEW COMPLETED |