Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0523-05252
Parcel: 128041530

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-RES-0523-05252
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/18/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0523-05252 (5512 E SOUTH WILSHIRE DR TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken.
Code reference, 2018 International Residential Code (IRC).

1. 1 ½” pipe is required for the external pipe from the meter to the Tankless WH T. Use Table G2413.4(1) (Metallic Pipe) to calculate correct required pipe sizes. 125’ length, 404CF/H. (length is measured from the meter to the furthest appliance, G2413.4.1).
2. 1 ¼” pipe is required from the Tankless WH T to the Stove T.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/18/2023 PDSD Application Completeness Express REVIEW COMPLETED