Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-RES-0523-05252
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/18/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/18/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0523-05252 (5512 E SOUTH WILSHIRE DR TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Code reference, 2018 International Residential Code (IRC). 1. 1 ½” pipe is required for the external pipe from the meter to the Tankless WH T. Use Table G2413.4(1) (Metallic Pipe) to calculate correct required pipe sizes. 125’ length, 404CF/H. (length is measured from the meter to the furthest appliance, G2413.4.1). 2. 1 ¼” pipe is required from the Tankless WH T to the Stove T. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 05/18/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |