Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0523-05096
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/05/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/05/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0523-05096 (6750 E BARROW ST TUCSON, AZ 85730) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Provide complete roof framing information for determining load carrying capacity of each structure supporting a collector group. Show size, spacing and span of all framing members including trusses, joists, rafters and beams, R301.1, R324.4. 2. Provide plans with wind and dead load calculations sealed by an Arizona engineer for the ballast solar assembly, R106.1, R301.1, R324.4. 3. Show the Main Service Panel with a main bonding jumper, R3607.5, 3609.4. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
05/15/2023 | PDSD Application Completeness | REVIEW COMPLETED |