Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0523-05054
Parcel: 11624056A

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2

Permit Number - TC-RES-0523-05054
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/21/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/21/2023 Residential Building REQUIRES RESUBMIT Permit Review #2 TC-RES-0523-05054 (103 S PANORAMA CI TUCSON, AZ 85745)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2018 International Plumbing Code (IPC).


1. Provide documentation of a utility easement for the sewer line that crosses a private property before connection to the county sewer system, Unified Development Code Article 7.12.
2. Show easement from building drain/building sewer connection all the way to the County sewer system.
3. Notate and specify all piping materials and sizes, P2608. Include existing building sewer pipe. Show Sewer line connections from building drain/building sewer connections all the way to the County sewer system.
4. Show tracer wire (#18 gauge minimum) from the cleanout at the building drain/building sewer connection run with the piping to the sewer tap, Pima County 0112.
5. Show all drainage fixtures with connection to the public sewer system, P2602.1. The gray water drain should be connected to the building drain within 3’ of the foundation.
6. Show a two-way cleanout at the building exterior, one-way cleanout at 100’ intervals and at change of direction exceeding 45 degrees, P3005.2.
7. Show all extension lines for future use with a permanent cap or plug, P3005.1.5.
8. All new sewer connections to Pima County system require a separate permit/activity-number from Pima County. Pima County Wastewater 520 724-6609 controls the tap point. https://www.pima.gov/government/wastewaterreclamation/. Provide Pima County permit/activity documentation.
9. NOTE: If you plan on doing a lot split for the two different addresses, then each dwelling requires an independent sewer connection from the dwelling to the County sewer connection. 2018 IPC 701.3.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
06/12/2023 PDSD Application Completeness Express REVIEW COMPLETED