Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0523-04999
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/23/2023 | Site Zoning | APPROVED | |||
05/24/2023 | Site Engineering | NOT REQUIRED | |||
06/02/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/02/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0523-04999 (7720 S WILMOT RD TUCSON, AZ 85756) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Provide an engineer’s calculation, design and seal for masonry partition and screen walls exceeding 7’ in height above grade, R301.1.3. The provided Proto II Fence Wall details page does not have an engineers seal. 2. The description of work states that the wall is 8’4”, but the max height of the Proto II Fence Wall details page is 8’. Either provide Sealed designs for a wall in excess of 8’, or correct the description of work to state 8’ max height. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
05/08/2023 | PDSD Application Completeness | REVIEW COMPLETED |