Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0523-04874
Parcel: 124050870

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0523-04874
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/25/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
05/24/2023 Historic REQUIRES RESUBMIT Resubmit the historic information under the historic sub-record.
05/25/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0523-04874 (713 E 5TH ST TUCSON, AZ 85719)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken.
Code reference, 2018 International Residential Code (IRC).

1. Plans show the removal of 3 different doors being removed and multiple windows being removed or resized. This requires complete building/framing plans to verify structural code compliance, R301.1.
2. Provide framing and header/lintel details and section views for the doors removed and windows modified, 301.1.
3. Provide emergency escape and rescue openings for every sleeping room, habitable attic and basement space. Net clear opening of 5.7 sf (5.0 sf allowed on grade floor rescue openings). Minimum 24 inches opening height, minimum 20 inches opening width. Sill height maximum 44 inches from finish floor to the bottom of the clear opening. IRC R310.1. The Windows in BDRM-3 are both in violation of emergency egress/access requirements.
4. The removal of the doors also requires plans Showing receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2, E3901.2.2 item 3. (All rooms with a door removed).

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/12/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0523-04874
711-713 East 5th Street – HR-2
Residential window replacements (1st Review)

TRANSMITTAL DATE: May 12, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The following comments are relative to an application for Historic Review (UDC 5.8.8)

1. Per UDC 5.8.8, HPZ review is required for alterations involving the modification, addition, or moving of any part of an existing structure that would affect the exterior appearance of the building. The requirements and application for historic review can be found at: https://www.tucsonaz.gov/files/pdsd/forms/Special_Districts_Application_Instructions.pdf.

Zoning cannot approve this building permit until the historic review is completed and approved.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
05/03/2023 PDSD Application Completeness REVIEW COMPLETED
05/04/2023 Site Engineering REVIEW COMPLETED
05/09/2023 Site Landscape REVIEW COMPLETED