Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0523-04865
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/08/2023 | Site Zoning | APPROVED | |||
| 06/23/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/23/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review 2nd submission TC-RES-0523-04865 (2055 W SILVER GRASS PL TUCSON, AZ 85745) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Code reference, 2018 International Residential Code (IRC). 1. Show ledger attachment to the house as connected to the wall framing below the top plate. You cannot attach the ledger to the truss or top plate, see figure R602.3(1). 2. Notate or detail a nailing pattern and nail type/size in compliance with Table R602.3(1) item 28 for a prescriptive design or provide an engineer’s sealed plan set for performance compliance consideration, R301.1.3. 3. Show 4x6 beams as Douglas Fir #1 equivalent or better to support the given span, R301.1. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 06/01/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |