Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-RES-0523-04844
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/08/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/08/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0523-04844 (511 N GOLLOB RD TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Code reference, 2018 International Residential Code (IRC). 1. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D. 2. Provide gas pipe size, length and type, P2609. Provide previous unit’s load demand, and new unit’s load demand for determining if existing gas pipe is sized correctly, Table G2413.4(1). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
05/02/2023 | PDSD Application Completeness | REVIEW COMPLETED |