Permit Number: TC-RES-0426-02226
Parcel: 12106253A

Address:
5737 E LEE ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.2

Permit Number - TC-RES-0426-02226
Review Name: RESIDENTIAL ADU v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/18/2026 Residential Engineering APPROVED
08/18/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/07/2026 Addressing Validation REQUIRES RESUBMIT For questions: PDSD-Permits@tucsonaz.gov

The permit and plan show to be for an Accessory Dwelling Unit (ADU) and requires to be separately addressed. Please submit a change of address request in order to properly update the location of this permit.

Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf
08/10/2026 Residential Building REQUIRES RESUBMIT Review the comments below and re submit.
1.Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Identify the ventilation requirements and insulation types for complying with the condensation control issues.
2. Show code compliant wall insulation.
3. R506.3.3 Vapor retarder: a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches is required between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist.
4.E3902.12 Appliance Outlets: GFCI protection is required for receptacle outlets or their branch circuit for:
1. Drinking water coolers
2. High pressure spray washing machines
3. Sump pumps
4. Dishwashers
5. Electric ranges
6. Wall-mounted ovens
7. Counter-mounted cooking units
8. Clothes dryers
9. Microwave ovens

5.. Please submit air leakage and duct tightness reports along with certificate as a deferred submittal.
6. Roof trusses will be a deferred submittal.
08/11/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston, Planner
PROJECT: TC-RES-0426-02226
5737 E Lee St., Tucson, AZ 85712
Detached ADU & Carport (2nd Review)

TRANSMITTAL DATE: 08/11/2026

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.


1. Per Comment 5 of the 5/20/26 Residential Zoning review, Zoning staff is unable to approve this resubmittal because the DDO application for TP-MOD-0826-000082 is still in process.
2. Once the DDO process is complete and the waiver period expired, please submit the following:

a. DDO Approval Letter
b. Revised site plan to include the following:
i. Required square footage of vegetative groundcover (shrubs may be substituted providing they cover the required square footage). Please refer to this link for landscape requirements: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code
ii. List the common names for the required groundcover/shrubs and the preferred watering method.
iii. Recalculate the Total Lot Coverage. Per UDC 6.4.3., total lot coverage basically includes all vehicle use areas and enclosed structures – (porches and walkways are excluded). This total is then divided by the square footage of the lot to arrive at the total lot coverage.
iv. Delete the Site Plan Note that references that vegetative ground cover is not intended because it is required.
c. Construction plans
d. A response letter addressing all staff review comments.

3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov
08/07/2026 PDSD Application Completeness Express REVIEW COMPLETED