Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0426-02149
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/27/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/27/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this request, please email PDSD-Permits@tucsonaz.gov 1) Please show or describe how whole home surge protection will be installed in the panel and resubmit. (Code references from the 2024 IRC are below: E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protection device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3. E3606.5.1 Location: the SPD shall be an integral part of the service equipment or shall be located immediately adjacent, if not located at each next-level distribution equipment downstream toward the load. E3606.5.2 Type: the SPD shall be a Type 1 or Type 2 SPD. E3606.5.3 Replacement: where service equipment is replaced, all of the requirements of this section shall apply.) |
||
| 04/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |