Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0426-02149
Parcel: 136190590

Address:
3309 S MEAD AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0426-02149
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/27/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/27/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT If you have questions regarding this request, please email PDSD-Permits@tucsonaz.gov

1) Please show or describe how whole home surge protection will be installed in the panel and resubmit. (Code references from the 2024 IRC are below: E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protection device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3. E3606.5.1 Location: the SPD shall be an integral part of the service equipment or shall be located immediately adjacent, if not located at each next-level distribution equipment downstream toward the load. E3606.5.2 Type: the SPD shall be a Type 1 or Type 2 SPD. E3606.5.3 Replacement: where service equipment is replaced, all of the requirements of this section shall apply.)
04/27/2026 PDSD Application Completeness Express REVIEW COMPLETED