Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0426-01950
Parcel: 134231290

Address:
210 S BUSCH PL

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW REVISION v.1

Permit Number - TC-RES-0426-01950
Review Name: RESIDENTIAL SIMPLE REVIEW REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/25/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/25/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov
Please resubmit a comment response letter and corrected plan set addressing the following comments:
1) The 3/4" pipe is undersized for the given length (first 10') and new appliance demand. Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) (Polyethylene Plastic Pipe), or Manufacturer’s sizing requirements.
Please revise the pipe size or verify demand of appliances matches with those listed on the gas template.

Note: Approximate distances of appliances is relevant to determine if the sizing of the fuel gas line from the meter is compliant. Provide this upon resubmittal

2) Please provide a revision narrative for any revisions to previously approved plans IBC 106.4
09/25/2026 PDSD Application Completeness Express REVIEW COMPLETED