Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0426-01935
Parcel: 133383000

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0426-01935
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/05/2026 Residential Building - Standard APPROVED
05/05/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/24/2026 Residential Engineering REQUIRES RESUBMIT Permit Activity Number: TC-RES-0426-01935 (1st Review)
Project: 30'x40' non-livable detached accessory structure for use as a garage/storage
Location: 10601 E CALLE NOPALITO
Review Date: 4/24/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files.

Reference Link for Final Plat: https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-29052&0

Site Engineering Review Comments:
1. In compliance with Final plat for Rancho Del Este – This property is Lot 283. It will be required that you delineate the 100-year floodplain limits as shown affecting the site through the official plat onto the provided site plan.
2. In accordance with General notes #6 & 14 – encroachment into said floodplain area will not be allowed.
3. In accordance with General notes #22 - it is required that the submission be completed for a separate floodplain use (FPU) permit application. The FPU permit is a separate permit that can be submitted within the sub-records of this residential permit through TDC Online.
a. The flood plain use permit is a final plat required FPU application, so all that will be required for submission will be the associated site plan.

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
04/29/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Claire Leighou, Planner

PROJECT: TC-RES-0426-01935

10601 E CALLE NOPALITO

30'x40' Non-livable detached accessory structure for garage/storage (1st Review)

TRANSMITTAL DATE: 4/29/26

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

This site is located in the RX-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .8, & .9.

Comment 1: Per the Unified Development Code (UDC) section 6.4.5.C.b., corner lot properties require a 20’ setback for the front yard and a 10’ setback for the secondary street facing edge/side yard. Property owners may choose which side is the front yard. Garages require a 20’ setback regardless of which side they are built. If part of the use of the proposed structure is a garage, the location should be relocated to 20’ from the west property line.

To retain the current proposed 5’ setback, you may apply for a Design Development Option (DDO), which could grant the reduced setback. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf. For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov or Georgia Pennington at georgia.pennington@tucsonaz.gov.

Comment 2: Please provide lot coverage calculations upon next submittal. Include total lot size/square footage, primary dwelling, proposed structures, existing sheds/accessory structures, and vehicular use areas, including driveways, parking spaces, carports/garages, and other vehicular maneuvering areas. Provide a total lot coverage calculation.

Comment 3: Please draw, dimension, and label vehicular use area(s), including driveway(s), carports, garages, and parking spaces, on the site plan.

Comment 4: Please provide the height of the existing labeled block walls on the site.

Comment 5: Based on aerial imagery of the site from 2024, there are two accessory structures on the property, one attached to the main home and one detached, as well as an attached carport in the front yard. Please draw, label, and dimension these structures on the site plan. Include height and square footage. Provide setback measurements for the carport to the south property line and the east accessory structure to the east property line. If any of these structures have since been removed, please make a note of this on the site plan. Please include these structures in the lot coverage calculations.

Comment 6: Please label the two adjacent streets, Calle Nopalito and Placita Churella.

Comment 7: Please include the zoning designation of the subject property and those surrounding, all of which are RX-1.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you!
04/20/2026 PDSD Application Completeness Express REVIEW COMPLETED