Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL FENCE/WALL v.2
Permit Number - TC-RES-0426-01917
Review Name: RESIDENTIAL FENCE/WALL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/18/2026 | Light Residential Building Review (OIP) | APPROVED | May require weep holes per engineering comments | ||
| 05/20/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/19/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-0426-01917 Location: 830 E 7TH ST Review Date: 5/19/2026 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. This previous comment was not addressed: A grading permit exists for the two SFRs: DP22-0115. Show floodplain limits in your next submittal on the site plan. https://tucsonaz.hylandcloud.com/221appnet2/docpop/docpop.aspx?clienttype=html&docid=5274645 2. Per comment response, Option 1 was picked: a. Option 1: build CMU wall out of the 100-yr floodplain limits. The wall will require venting for drainage into the wash. b. The wall remains within the boundary of the 100-yr floodplain and will require the drawing to accurately reflect the 100-yr limits, and the location of the wall with venting. 3. Resubmit a comment response and a corrected site plan for engineering review. If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 05/20/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0426-01917 830 E 7th St. Unit 1., Tucson, AZ 85719 Retaining Wall (2nd Review) TRANSMITTAL DATE: 05/20/2026 This site is located within the NR-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Please see Residential Engineering comments provided on 5/19/26 regarding wall venting and location, a corrected site plan and response letter. Site Zoning is unable to approve an acceptable site plan until these comments have been addressed and approved by Residential Engineering. 2. Resubmit a site plan specific to this request as requested in the Comment 1 of the 4/24/2026 Residential Zoning comments which provided specific details. Please follow the link provided ( https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/basic-site-plan_feb2026.pdf ). The scope needs to include only the wall; not the pool. Do not use previously City-stamped plans. 3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 05/14/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |