Permit Number: TC-RES-0426-01886
Parcel: 122060710

Address:
4208 E SENECA ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.3

Permit Number - TC-RES-0426-01886
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/21/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/20/2026 Residential Building - Standard REQUIRES RESUBMIT Please provide construction documents of the carport, anchoring, posts, rafters, material, ect. Please re submit.
07/21/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Georgia Pennington, Lead Planner

PROJECT: TC-RES-0426-01886
4208 E Seneca St., AZ 85712
Detached Carport (3rd Review)

TRANSMITTAL DATE: 7/21/2026

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Please resubmit a site plan and clearly show the project area. The image is insufficient for a Site Zoning review. Please refer to this Full site plan example link: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/full-site-plan_feb2026.pdf

Please use the following link which shows the New Sierra Addition Lot 6 Blk 1 dimensions. This is the legal description of the lot. https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=08005

Please also provide the distance measurements from the carport to the lot lines and the carport to any nearby structures. All structures are to be shown on the site plan.

Setbacks are required to be shown on the site plan. Setbacks for the zoning district are 5’ from the rear and side property lines and 20’ from the front property line per Ordinance No. 12219, an amendment to the Unified Development Code (UDC), which went into effect on January 1, 2026.

2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

If you have any questions about this transmittal, please contact Georgia.Pennington@tucsonaz.gov
07/16/2026 PDSD Application Completeness Express REVIEW COMPLETED