Permit Number: TC-RES-0426-01879
Parcel: 136202100

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.1

Permit Number - TC-RES-0426-01879
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/20/2026 Residential Building APPROVED
05/04/2026 Residential Engineering APPROVED Exterior accessible route shall conform to 2017 ICC A117.1 Sections 402 and 403 and City of Tucson Inclusive Home Design Ordinance. Water draining from roof shall not interfere with exterior accessible route.
05/04/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/20/2026 Addressing Validation REQUIRES RESUBMIT For questions: PDSD-Permits@tucsonaz.gov

This permit appears to be for an ADU and there are two units linked to this parcel. A change of address request must still be submitted through the sub records of this permit to add the ADU unit number to this permit. Please resubmit construction plans with full address and unit number on each page after this review is complete.

Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf
04/29/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Erick Bieber
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0426-01879
8318 E Wildcat Dr, Tucson, AZ 85730
Residential ADU - Casitas (1st Review)

TRANSMITTAL DATE: April 29th, 2026

This site is zoned O-3 (UDC Section 4.7.15). An accessory dwelling unit is a permitted use in this zone (Table 4.8-5) subject to Use Specific Standards 6.6.3.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. (Comment) Zoning is unable to locate permits for the Storage Unit accessory structure indicated in the southwest of the property. Previously approved plans (T22CM04956) indicated the accessory structure with a note “TO BE REMOVED / TEMPORARY STRUCTURE”. Please submit a separate Residential Addition/Alteration permit for the accessory structure or provide proof of its demolition.

2. (Comment) The Middle Housing Code Amendment requires basic drought resistant landscaping to be indicated on the site plan for 1–4-unit residential projects submitted starting in 2026. The requirements include but are not limited to:
a. One canopy tree required for every 1,000sqft of gross floor area of the development project (1-1,000sqft – 1 tree, 1,001-2,000sqft – 2 trees). The GFA of this project would require 1 canopy tree.
b. 5 feet of vegetative groundcover for the length of the street frontage, minus the curb cut width. For this lot, approximately 120sqft of vegetative groundcover will be required.
c. Landscaping requirements may be met by existing landscape features on the site, but the existing landscaping must be indicated on the site plan. Please indicate existing on-site landscaping on the site plan.
d. See the following link for the full Middle Housing Ordinance:
https://middle-housing-cotgis.hub.arcgis.com/

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov
04/20/2026 PDSD Application Completeness Express REVIEW COMPLETED