Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0426-01806
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/24/2026 | Residential Building - Standard | APPROVED | |||
| 04/15/2026 | Residential Engineering | NOT REQUIRED | |||
| 04/24/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/23/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0426-01806 2612 E Crosby Vista, Tucson, AZ 85713 Attached Pergola (1st Review) TRANSMITTAL DATE: 04/23/2026 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. The site plan proposes a side setback of the attached pergola extension of 4’ into the required 5’ east side setback (UDC Use Table -6.3-2.A) . Due to the reduced setback request, a DDO is required per Unified Development Code (UDC) 6.4.5.C.1.a. To submit an application for a DDO, visit www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo-for-setback-and-height.pdf Submit the DDO application under the Zoning Modification sub-record that you will create. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf If you have further questions regarding the DDO process, please contact Georgia Pennington at georgia.pennington@tucsonaz.gov . This process will take about 6 weeks. Once the application has been deemed complete and the appeal period is over, Site Zoning is unable to approve permit TC-RES-0426-01806. Please attach a copy of the DDO decision letter with the next submittal packet. 2. The site plan is incomplete. Please visit the following link to the Basic Site Plan example: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples and provide the missing information. 3. Provide elevations for the pergola. Per the Unified Development Code (UDC) 6.4.4.B1, the height of all structures is the vertical distance measured from design grade at the base of the structure at all points along that structure to the top of the structure. For structures within six feet of a property line, the design grade used for measuring height is the lower of the two grades on each side of that property line. 4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code Amendment to the UDC via Ordinance No. 12219, effective 01/01/2026: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/middle-housing/middle-housing-ordinance-clean.pdf If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov |
||
| 04/15/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |