Permit Number: TC-RES-0426-01762
Parcel: 116212790

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.1

Permit Number - TC-RES-0426-01762
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/13/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/15/2026 Addressing Validation REQUIRES RESUBMIT For questions: PDSD-Permits@tucsonaz.gov

The permit and plan show to be for an Accessory Dwelling Unit (ADU) and requires to be separately addressed. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to assign/add the units or a new address for this ADU. Please resubmit your plans and all supporting permit documents to reflect the updated address, in addition, a change of address request will need to be submitted in order to properly update the location of this permit to the ADU address.

Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf
05/13/2026 Landfill Standard REQUIRES RESUBMIT Permittee must review Landfill Ordinance 10037 and applicability of 500-foot proximity to a landfill.
https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-22345
The Landfill Ordinance Self-Certification Statement Form must be completed and submitted for approval.
04/16/2026 Residential Building REQUIRES RESUBMIT Provide a complete construction plan set showing 2024 IRC and City of Tucson building ordinance compliance after DDO approval.

Any structure placed in the 3-foot fire separation distance from the adjoining (neighboring) property line requires not less than one-hour fire-resistive construction for reducing fire spread across the property line, R302.1. The fire rated wall may not have window or door openings. Fire rated materials are found in IBC Table 721.1(2), Items 15-1.1 to 16-1.3.
04/28/2026 Residential Engineering REQUIRES RESUBMIT Permit Activity Number: TC-RES-0426-01762 (1st Review)
Project: ADU
Location: 923 W NEARMONT DR
Review Date: 4/28/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files.

Site Engineering Review Comments:
1. Ensure to address all of Site Zoning comments regarding documentation and site plan requirements/expectations.
If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
04/23/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-0426-01762 –Residential Building – ADU
923 W NEARMONT DR TUCSON, AZ 85745 (R-2 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: April 23, 2026

This site is in the R-2 Residence Zone (UDC 4.7.9). An accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3.

The City's Unified Development Code (UDC) (Section 1.4.1.C) establishes that before the City issues any approvals or permits; we must confirm that a site complies with UDC standards. Therefore, as part of permit reviews, we review a site's permit history and compare it to aerial photography to confirm that unpermitted work has not occurred. In many cases, this does mean that a homeowner must apply for permits for unpermitted work before we can approve any new work on that site.

Plan review for the above referenced accessory dwelling unit (ADU) has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: Refer to Building Reviewer comments regarding building specific drawings that demonstrate meeting current building code.

2. COMMENT: The site plan provided is incomplete.

Specifically:

A. Draw, label and dimension everything that exists on the property to a scalable drawing graphic (examples include the principal residence, porches, breezeways, sidewalks, driveways, parking spots, walls, fences, ramada, shed, carport, shade sail, cistern, pool, guest house, sleeping quarters, accessory dwelling unit) and provide dimensions of any structure as it relates to nearby structures and property lines and provide the heights (measured from above finish grade to top of wall, etc.) of those structures that run parallel-perpendicular to any nearby adjacent property lines. Provide heights at various locations along the fence/wall if applicable. Label missing parking (if applicable).

The site plan is missing the unpermitted shade sail over the front driveway. Draw, dimension and label shade sail.

B. Update the four property dimension lengths per https://www.asr.pima.gov/ParcelData/Map/Arm/MP03/M03043.PDF

C. Provide the missing legal description: P S HUGHES W50' E263.15' LOT 18
LYG S NEARMONT DR

D. Add the 5’-0” dimension to the proposed ground cover bed.

E. Provide R-2 zoning labels on all four sides of this parcel.

F. Remove Neighbor Waiver information (per Comment 4 below).

3. COMMENT: Per UDC 6.6.3.C. standard, detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and front street lot line, except for shade structures or carports not over 400 square feet in floor area, terraces and steps not over three high above the natural grade, paved areas, and fences or walls.

As previously stated, draw, label and provide dimensions of the unpermitted shade sail in the front yard over the driveway.

Per TABLE 6.4.5.C.1.a., “For single-family and duplex development, the minimum required street perimeter yard is 20’-0” measured from the street property line”

Additionally, per 6.4.5.D.3.a. “Shade structures or carports may project up to 10’-0” into required perimeter yards. Such architectural features include, but are not limited to, overhangs, moveable insulating walls and roofs, detached solar collectors, reflectors and piping”

Also, per UDC 6.4.5.C.1.c.(2), For carports, if the distance between the back of street curb and the carport is eight feet or less, a minimum of one foot must be provided.

Per google street view, it appears the shade goes all the way to north property line.

Two options exist:

A. Remove shade sail.

B. Leave the design as-is and attempt to secure relief from this standard through the Board of Adjustment Variance process. See below for more information on the B/A Variance process.

Zoning cannot approve this permit until the Board of Adjustment (B/A) Variance Process is completed and approved.

See below for more information on the B/A Variance process.

4. COMMENT: Per Ordinance 12219, the rear and side yard setbacks are now 5’-0”. As currently depicted, the dimensions to the south and west (1’-0”) do meet these standard and being a detached, habitable structure, will require an attempt to seek setback relief;

a) via a Design development Option (DDO) if you change the dimensions to 1’-1”.

Know this is an extra 6-week review and the neighbors within 100’-0” are made aware of this attempt to seek relief from being in the setback. Zoning will not be able to approve this permit application until the DDO is approved. This information is linked here:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3

To submit a DDO application, apply for a new sub-record under this permit at TDC Online:

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

See below for more information on the DDO process.

b) Board of Adjustment Variance to maintain 1’-0” dimensions as currently shown:

A board of adjustment variance will be required to permit the structure as shown on the site. See variance requirements below. Zoning cannot approve this permit until the Board of Adjustment (B/A) Variance Process is completed and approved.

See below for more information on the B/A Variance process.

c) COMMENT: After reviewing the property documentation history in Property Research Online (PRO), zoning could not verify any permit documentation for the existing shade sail installed around 2021 in the front setback over the driveway.

Zoning will not be able to approve the permit application until the permit information is provided. If permit documentation cannot be provided, this shade sail may be added to this permit provided you meet comment #3 and get Board of Adjustment Approval.

5. COMMENT: Zoning has acknowledged this property has a structure on-site with a with ‘contributing status’ with the National Register of Historic Places and advises the owner to contact the State Historic Preservation Office (HPO) to determine if this project will impact the status. Contact https://azstateparks.com/SHPO for more information. This comment is purely made as a courtesy as there may be tax implications. No action is required and is at the discretion of the owner.

6. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov

DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration . Note that multiple DDO’s can be submitted concurrently on the same application.

To submit a DDO application, apply for a new sub-record under this permit at TDC Online. In order to get this specific review scheduled and if you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. Zoning cannot approve the zoning review portion of the permit until the DDO has been approved.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit

2. Provide a detailed response letter (clarification narrative) with your submittal that clearly shows how you have addressed all Zoning comments.

3. Resubmit ALL documents associated with this permit

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
04/15/2026 PDSD Application Completeness Express REVIEW COMPLETED