Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0426-01701
Parcel: 104092270

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0426-01701
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/23/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/23/2026 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-0426-01701
Location: 4010 N FAIRVIEW AV
Review Date: 6/23/2026
A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal.

Residential Engineering Comments:
1. The proposed new dwelling is located at an intersection of two Collector road-types associated with Major Streets & Routes (MS&R) that are set to expand. The proposed project must have approval by right-of-way (ROW) and conform to the planned road expansion (future right of way/FROW) and setbacks associated with said FROW. For questions, please contact Zane.Swenseon@tucsonaz.gov.
2. Sight visibility triangles must be shown for current ROW and future ROW. Collector – Collector: Near = 255’, not 110’. Drive – Collector: Near = 265’, Far = 110’. The SVT provided are not scaled to the dimensions required.

If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov
06/15/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston, Planner

PROJECT: TC-RES-0426-01701
4010 N Fairview Av., Tucson AZ 85705
SFR (2nd Review)

TRANSMITTAL DATE: 06/15/2026

This site is in the MU Residence Zone (UDC 4.7.23). A single-family residence is permitted use in this zone (Table 4.8-7).

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Comment 1 from the April 21, 2026 Zoning review from Jeffrey Cassidy stated that Zoning cannot approve this permit until the demolition permit is approved. As of this date, the demolition permit has not been approved and was requiring a resubmittal as of Friday, June 12, 2026. Please wait until the demolition application (TC-DMO-0626-00092) has been approved before resubmitting TC-RES-0426-01701.

2. Provide a response letter addressing all staff comments for the next submittal round.

3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .

If you have any questions about this transmittal, please contact Roxanne Johnston, at roxanne.johnston@tucsonaz.gov .
06/22/2026 ROW Engineering Review Standard REQUIRES RESUBMIT DTM Review Comments -
1) Call out Driveway Compliance with PAG 206 Standard Detail & TSM 10-01.4.3
2) Review Redline not on Plans - Max Driveway width is 20'
3) DTM will not be requiring Sidewalk placement as part of this project - Current DTM planning in progress for the Widening and Safe improvements of Fairview Av. Expansion to the Listed MS&R width of 64', may provide Expansion of the 19' to the Eastside of Fairview Av. Sidewalk will not be required as part of this review.
4) Note: Separate permit from DTM will be required through the TCD portal for all work performed in the Right of Way.
06/11/2026 PDSD Application Completeness Express REVIEW COMPLETED