Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0425-02287
Parcel: 116261480

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0425-02287
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/01/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/01/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Permit Review TC-RES-0425-02287 (2517 W CALLE PARAISO TUCSON, AZ 85745) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide an updated Plan and a written response letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response letter addressing the comments below maybe be delayed until the response letter is received. For questions: Building_Official@tucsonaz.gov

1. For the given pipe length and 199,000 BTUs, the pipe segment running to the water heater is undersized and requires to be a minimum of 1'' per Table G2413.4(7).

2. Minimum burial depth 18'' for non-metallic pipe, G2415.12

3. Yellow tracer wire required for non-metallic pipe, G2415.17.3
4. See drawing for markups.
04/30/2025 PDSD Application Completeness Express REVIEW COMPLETED