Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0425-02232
Parcel: 112031380

Address:
2920 E FARR ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0425-02232
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/27/2025 Residential Building - Standard APPROVED
06/04/2025 Site Engineering - Standard NOT REQUIRED
06/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/29/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-0425-02232
2920 E Farr Street Tucson, AZ 85716
Bathroom addition and renovate family room (1st Review)

TRANSMITTAL DATE: 5/29/2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference.
2. Comment: Please draw, label, and dimension the rear alley which measures 20’.
3. Comment: Please draw, label, and dimension the ½ Right of Way from the centerline to the base of the wedge curb and from the base of the wedge curb to the property line along E. Farr Street. https://maps-and-records.tucsonaz.gov/construction-plans/details/G-375.
4. Comment: Per Maps and Records (MP-09-008), there is a 5’ utility easement that runs along the West property line. Please draw, label, and dimension this easement. https://maps-and-records.tucsonaz.gov/subdivisions/details/1231.
5. Comment: The provided lot coverage calculations are incorrect. Per UDC 6.4.3.C.1, pools and patios are not included in lot coverage calculations, however the existing storage sheds need to be included. Please remove the swimming pool and patio area, add the existing storage sheds to the lot coverage, and update the calculations to accurately reflect the total lot coverage.
6. Comment: Zoning was unable to find an associated permit for the existing storage sheds. Please dimension the setbacks for these storage sheds to the West property line. If these storage sheds do not meet the minimum required setback (greater of 6’ or 2/3 Height of the proposed wall), a neighbor waiver can be utilized to reduce the minimum required setback however the sheds cannot be placed in the utility easement without written permission from the associated utility companies. The neighbor waiver needs to be included on the site plan. If a neighbor waiver cannot be obtained, a Design Development Option (DDO) may be used to reduce the minimum required setback. DDO comments cannot be made at this time as the setbacks were not provided for the sheds. Here is a sample neighbor waiver:
My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan.
Signature: _____________________________ Date: _________________________________
7. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.
If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
04/29/2025 PDSD Application Completeness Express REVIEW COMPLETED