Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0425-02212
Parcel: 134110230

Address:
7934 E 18TH PL

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0425-02212
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/28/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Permit Review TC-RES-0425-02212 (7934 E 18TH PL TUCSON, AZ 85710)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans and a written response letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response letter addressing the comments below maybe be delayed until the response letter is received.


1. Aerial views and your site plan of the property show the overhead service conductors will be passing over the roof. Please indicate that the overhead service conductor over the the "Roofline" requires an 8’ clearance above the roof, E3604.2.1. The 8’ clearance is required to be maintained for a distance of 3’ from the edge of the roof. For questions: Building_Official@tucsonaz.gov
04/28/2025 PDSD Application Completeness Express REVIEW COMPLETED