Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0425-02212
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/28/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | Permit Review TC-RES-0425-02212 (7934 E 18TH PL TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans and a written response letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response letter addressing the comments below maybe be delayed until the response letter is received. 1. Aerial views and your site plan of the property show the overhead service conductors will be passing over the roof. Please indicate that the overhead service conductor over the the "Roofline" requires an 8’ clearance above the roof, E3604.2.1. The 8’ clearance is required to be maintained for a distance of 3’ from the edge of the roof. For questions: Building_Official@tucsonaz.gov |
||
| 04/28/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |