Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0425-02208
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 06/04/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/29/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0425-02208 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Provide a response letter on separate file when submitting the updated construction plan set. Provide the construction plan set in a single PDF file including a site plan. Provide a clear and concise construction plan set. Review the sample drawings for a wooden Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Indicate the location of the proposed building and existing overhead electrical line, R106.1.1. Show the utility lines requiring relocation. SECTIONS - DETAILS: 1 Show the post to footer fastener with 1” gap post base hardware, R407.3 & R507.4.1. 2 Show roof sheathing and fastening in compliance with Table R602.3 (1). 3 Note the rafter to a load bearing wall fasteners, R606.11. 4 Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. ELECTRICAL PLANS: |
||
| 06/02/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0425-02208 9090 E Sugar Sumac St. Tucson, AZ 85747 Patio Cover (1st Review) TRANSMITTAL DATE: 6/2/2025 This site is located in the R-3 zone (Unified Development Code (UDC) Article 4.7.12). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Site zoning is unable to conduct a full review with the submitted documents. Please include a site plan showing the entire property in your next submittal which includes the location of the patio and associated setbacks to the nearest property lines. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference. 2. Comment: Additional comments may be forthcoming depending on the updated plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 05/01/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |