Permit Number: TC-RES-0425-02206
Parcel: 10712230B

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0425-02206
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/11/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/15/2025 Addressing Validation REQUIRES RESUBMIT Please resubmit site plan with full property address on each page once other reviews are complete.
08/04/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0425-02206 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings.

The plans show a new dwelling (rather than an sleeping quarters addition) which requires a Pima County assigned address (unit number) shown at each dwelling on the site plan. https://www.pima.gov/1010/Addressing-Frequently-Asked-Questions

Provide a response letter addressing each comment with sheet number location where the change is located. Submit separate letter and plan set files.

GENERAL COMMENTS :

1. Show one-hour fire-resistive construction in compliance with IBC Table 721.1(2) for the separating wall between units. Provide a separating wall detail showing the proposed materials for compliance.

SITE PLAN:

1. Show the location of the electrical service line (overhead or underground) between the pole and service panel, R106.1.1. An overhead service conductor requires an 8-foot clearance above the proposed roof, E3604.2.1. Check with TEP customer service for electrical line options of raising the conductors or relocating the service panel.

PLUMBING PLANS:

1. Show the water heater capacity rating, P2801.1. The electric circuit is sized for the rating requirement.
2. Show a two-way cleanout at the building exterior, at 100’ intervals and at change of direction exceeding 135 degrees, P3005.2

MECHANICAL PLANS:

1. Provide heating/cooling facilities in all habitable rooms, R303.9. Show the equipment location and rating for demand requirement.
2. Provide (fresh air intake flow rating) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Identify the device model number providing an adjustable setting and note the minimum continuous setting. A one-bedroom dwelling under 1501 SF requires a 30 CFM continuous setting.

ELECTRICAL PLANS:

1. Update the Riser Diagram showing a new sub-panel for serving the ADU, NEC 225.30 and E3403. Show a sub panel feeder size and appropriate main breaker, E3602.1 & E3603.1.
2. Note that all smoke alarms must be interconnected with a power source from the building wiring and be equipped with battery backup, R314. Show the circuit number on the ADU sub panel schedule.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place within the dwelling or electrical panel, N1101.14. Add notation to plans.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
08/11/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-0425-02206 – Residential Building – New ADU
19 W Florence St Tucson, AZ 85705 (O-3 Zoning)
Building Plan Review – 2nd Review

TRANSMITTAL DATE: August 11, 2025

This site is in the O-3 zone (UDC 4.7.15). A single-family residence is a permitted use in this zone (Table 4.8-3).

Plan review for the above referenced ADU has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:
The scope of this plan review covers zoning, use(s), legal description, adjacent properties, setbacks (building or wall heights), dimensional standards, property permitting history, density (units/lot size), and lot calculation (enclosed building and structure, parking, and driveway versus overall lot size) requirements. All code references are to the Tucson, AZ Unified Development Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
Correct the following plot (site) plan, as noted in the comments below, along with a detailed response letter indicating responses to the review comments.

PLANS:

1. COMMENT: Correct the following on the Site Plan sheet (A1.0):
a) The property dimensions on the Site Plan (A1.0) don’t match the Subdivision Plat Map.
b) See CS1.0 Plot Map for correct dimensions.
c) Correct the property line graphic in the northwest corner of the property to be consistent with Subdivision Plat Map.
d) Adjust Lot calculation numbers based on new property dimensions.
e) Add missing zoning classification for eastern neighboring parcel.

2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other the PDSD reviewer comments.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .

Please contact the zoning reviewer if you have any zoning questions:

Jeffrey W Cassidy
City of Tucson Site Zoning and Planning Reviewer
jeffrey.cassidy@tucsonaz.gov / (520) 837-4916

Additionally, our in-person counter at the Public Works building at 201 N Stone Ave Tucson, AZ 85701 is open and available Monday thru Thursday, 8am-12pm. Ask to speak with me for an in-person consultation to go over my comments if you feel this option will better serve your follow up needs.

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
07/15/2025 PDSD Application Completeness Express REVIEW COMPLETED