Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-0425-02119
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/24/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/24/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0425-02119 3730 S Serena Ln. – R-1 New pre-engineered aluminum awning (2nd Review) TRANSMITTAL DATE: July 24, 2025 Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 1. This comment was not addressed correctly. Per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage. Please include the lot coverage calculations as noted in the sample plot plan 2. This comment was not addressed correctly. Per Sheet 5 of Construction Plan I-2020-006 the distance from centerline of Serena to the face of curb is 15’ and from face of curb to property line is 10’. Please draw, label, and dimension the ½ Right of Way from the centerline to the base of the wedge curb and from the base of the wedge curb to the property line along S. Serena Lane. Refer to paving improvement plan I-2020-006 if necessary. https://maps-and-records.tucsonaz.gov/construction-plans/details/I-2020-006. 3. This comment was not addressed correctly. Per UDC Article 6.4.5.C.1.a the street perimeter yard setbacks are measured to the street property line. Also, per UDC Article 6.4.5.B.2 perimeter yard setbacks for a carport type structure a measured from the post supporting the structure as long as the roof overhang is not greater than 2’-0”, UDC Article 6.4.5.C.2.a.(2). No setback dimension was provided from the proposed carport to the west property line. Please clearly label the dimensions from the property line to each side of the new carport as the dimensions are not the same due to the shape of the property. 4. The “S SIDE 8’’ street perimeter yard setback is not correct. Review UDC Article 6.4.5.C.1.a the required setback is 20’. It appears that the 20’ setback will not be met. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/25/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |