| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/03/2025 | Site Zoning | NOT REQUIRED | |||
| 07/03/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/26/2025 | Residential Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0425-02118 V. 4 PROJECT: RESIDENTIAL POOL ADDRESS/PARCEL: 1715 N MARIPOSA WOODS PL Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Swimming Pool and Spa Code, 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. COMMENTS: 1. Site Plan is missing Access Arrow 2. Site Plan is illegible – the reviewer cannot read the numbers on the set back – please increase the paper size from letter to ledger 3. Remove the deck from the site plan – it is unnecessary 4. Site plan is missing Parcel dimensions – see sample site plan here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf 5. Site plan is missing the electrical home run length from the equipment to the main panel 6. Site plan is missing the gas line run from the heater to the gas main. Please include the length, the diameter, and the number of BTUs for the heater on your site plan. 7. Site plan is missing any and all information about the barrier and barrier code requirements. 8. Site plan is missing the dimension from the house to the water’s edge of the pool. 9. What is the height of the raised spa? If it is 18” – please show tiled handholds across the face of the spa if they are required on the construction drawing. Please upload your revised plans to TDC-Online with a revision letter outlining what has been revised on the doc set. Resubmittals will not be accepted without the revision letter that answers all of the above comments. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov |
||
| 06/23/2025 | Site Engineering | REQUIRES RESUBMIT | Permit: TC-RES-0425-02118 Location: 1715 N MARIPOSA WOODS PL Review Date: 6/23/2025 Site Engineering Comments: 1. This project lies within a recognized floodplain and requires a Floodplain Use Permit (FUP) along with an elevation certificate. Please start a new FPU at our permit application web page: https://tdc-online.tucsonaz.gov/#/home 2. Site engineering will be unable to approve the associated residential building permit TC-RES-0425-02118 until the associated Floodplain Use Permit (FPU) is reviewed and issued. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 06/23/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |