Permit Number: TC-RES-0425-02069
Parcel: 111060650

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.3

Permit Number - TC-RES-0425-02069
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/13/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/08/2025 Addressing Validation REQUIRES RESUBMIT You do have unit in our system but will need to submit a change of address request in sub records. It should be found under "Request Change of Address". Please request a change of address through sub records of this permit. Here are some instructions for navigating sub-records: chrome-extension://efaidnbmnnnibpcajpcglclefindmkaj/https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf Also please resubmit revised site plan with comment response letter addressing all reviewers previous comments. Ensure unit numbers are included on address of updated site plan. For questions: Building_Official@tucsonaz.gov
09/30/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0425-02069 2nd

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

PLANS:

1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include a side hinged exit door, R311.2. The code does not allow an exception for one egress hinged door. Manufacturers provide combination sliding and hinged units.

ELECTRICAL PLANS:

1. Show receptacles within 2’ of counter edges or corners and no more than 4’ apart, E3901.4.1. Receptacles are required at each side of the kitchen sink for this requirement.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
10/13/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL
FROM: Roxanne Johnston
Planner
PROJECT: TC-RES-0425-02069
2917 N Dodge Bl., Tucson, AZ 85716
ADU (3rd Review)

TRANSMITTAL DATE: 10/13/2025

This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. The current site plan does not fully address the requirement for ADA access. Per the City of Tucson Inclusive Home Design Ordinance : https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf
all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Although the language is provided on Sheet C2, please demonstrate an ADA accessible pathway to a public area within the site plan.

2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

For questions regarding Zoning comments, please contact me at: roxanne.Johnston@tucsonaz.gov
09/08/2025 PDSD Application Completeness Express REVIEW COMPLETED