| 05/16/2025 | Residential Building - Standard | APPROVED | |||
| 05/22/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 05/22/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/18/2025 | Addressing Validation | REQUIRES RESUBMIT | Fix address on first page of site plan to match permit | ||
| 05/21/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0425-02062 9140 E 8TH ST. – R-1 Carport Extension (1st Review) TRANSMITTAL DATE: May 21, 2025 Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 – 9. 1. Per UDC Article 6.4.5.D.2.a.(2) The roof overhang may only extend two (2) feet into the required 10’-0” street perimeter yard setback, UDC Article 6.4.5.D.3.a. Based on a 2’-10” roof overhang the proposed front street perimeter yard setback from the allowed 2’ over hang is 9’-2”. A Design Development Option (DDO) will need to be submitted and approved. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. 2. Remove the reference to “*7’-0” SETBACK PER C.O.T. R-1 ZONING” and the setback line from the site plan as the refences is not correct, see UDC Table 6.3-2.A. 3. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example,. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 04/18/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |