Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0425-02062
Parcel: 133323520

Address:
9140 E 8TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0425-02062
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/16/2025 Residential Building - Standard APPROVED
05/22/2025 Site Engineering - Standard NOT REQUIRED
05/22/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/18/2025 Addressing Validation REQUIRES RESUBMIT Fix address on first page of site plan to match permit
05/21/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-0425-02062
9140 E 8TH ST. – R-1
Carport Extension (1st Review)

TRANSMITTAL DATE: May 21, 2025

Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 – 9.

1. Per UDC Article 6.4.5.D.2.a.(2) The roof overhang may only extend two (2) feet into the required 10’-0” street perimeter yard setback, UDC Article 6.4.5.D.3.a. Based on a 2’-10” roof overhang the proposed front street perimeter yard setback from the allowed 2’ over hang is 9’-2”. A Design Development Option (DDO) will need to be submitted and approved. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

2. Remove the reference to “*7’-0” SETBACK PER C.O.T. R-1 ZONING” and the setback line from the site plan as the refences is not correct, see UDC Table 6.3-2.A.

3. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example,.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
04/18/2025 PDSD Application Completeness Express REVIEW COMPLETED