Permit Number: TC-RES-0425-02009
Parcel: 107050630

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0425-02009
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/17/2025 Site Engineering - Standard NOT REQUIRED
06/09/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/08/2025 Light Residential Building Review (OIP) - Standard REQUIRES RESUBMIT Permit Review TC-RES-0425-02009 (703 W FLORENCE ST TUCSON, AZ 85705). Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC).
1. Where live parts of electrical equipment are operating at 50 to 1000 volts, such equipment shall be guarded against accidental contact by approved enclosures or other approved means, NEC110.27(A).
2. Where subject to physical damage, conductors, raceways, equipment, and cables shall be protected. The ground mounted system is in the front yard near the vehicle driveway. NEC 300.4 Protection Against Physical Damage, NEC110.27(B) Prevent Physical Damage.
3. Provide structural calculations Sealed and signed by an Arizona registered Engineer.
Provide a list of any special inspections required.
4. Provide a Special Inspection Certificate, with Parts A and B completed. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf

5. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability for 115 MPH, or provide an engineer’s calculation, and sealed design, R301.1, R324.4. An IRC PV roof uplift calculator (XLS) is available on Pima County’s website. https://www.pima.gov/1069/Solar-Wind-Systems

Building_official@tucsonaz.gov
06/09/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Krista Hansen
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0425-02009
703 W FLORENCE ST TUCSON, AZ 85705
Residential Solar (1st Review)

TRANSMITTAL DATE: 06/09/2025


This site is located in the MH-1 zone (UDC 4.7.10). A single-family residence is a permitted use in this zone (Table 4.8-2).


01. COMMENT: Per UDC Table 6.3-2.A, the minimum rear and side yard setbacks are 6’-0” or 2/3 the height of the exterior building/structure wall, whichever is greater. Based on the proposed ground mounted solar with a maximum height of 5’-6”, the required setback would be 6’-0”. The setback for the proposed structure is 4’-6” from the south property line.

Per UDC Article 6.6.2.D, a detached accessory structure within a perimeter yard shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built up to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the site plan and be signed and dated by the adjacent property owner (702/704 W GLENN ST):

My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________


02. COMMENT: Based on aerial photos it appears that the existing storage sheds (one on the southeast property line and three on the southwest property line) appeared between 2006 and 2010. Zoning was not able to find approved permit documents for these additions. They also appear to not meet setbacks on the south, east, and west property lines, which are 6’-0” or 2/3 the height of the exterior wall, whichever is greater.

As stated in comment 1, detached accessory structures may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the site plan and be signed and dated by the adjacent property owner(s) (702/704 W GLENN ST, 713 W FLORENCE ST, 643 W FLORENCE ST):

My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________



RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments above, along with a detailed response letter indicating how all Site Zoning comments were addressed. Instructions for resubmittal: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

For questions regarding Zoning comments, please contact me at: Krista.Hansen@tucsonaz.gov
04/17/2025 PDSD Application Completeness Express REVIEW COMPLETED