Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0425-01983
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/13/2025 | Residential Building - Standard | APPROVED | |||
| 05/14/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 05/14/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/14/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0425-01983 1750 E MISSOURI ST. – R-2 Attached Carport (1st Review) TRANSMITTAL DATE: May 14, 2025 Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of less than 9’-0” the required perimeter yard setback from the proposed carport to the west property line is 6’-0”. Perimeter yard setbacks for a carport type structure are measured from the post supporting the structure to the applicable property line. As a dimension from the post to the west property Zoning assuming that the proposed perimeter yard setback from the carport to the west property line is 0’-0”. A Board of Adjustment for Variance will need to be submitted and approved to reduce the setback to less than 1’-0”. If you can provide a minimum 1’-0” setback from the proposed carport post to the west property line the reduced setback can be processed using a Design Development Option (DDO) which can save the owner time and money. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/15/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |