Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0425-01942
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/07/2025 | Residential Building - Standard | APPROVED | |||
| 05/22/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/14/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | TC-RES-0425-01942 2750 W PLACITA SOMBRA CHULA Site engineering comments are as follows: 1. This project requires a separate Development Package that shall include a grading plan and NPPO. Include the area of disturbance and cut/fill quantities on the grading plan. The grading plan must meet the standards described in TSM 2-01.4.1. 2. Provide Average Cross Slope (ACS) calculations. The amount of developable area is determined by Unified Development Code TABLE 5.2-1. 3. The Development Package must be approved by all reviewers and issued prior to the approval of this permit submission. UDC Article 3.3.3.7.a Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
||
| 05/14/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Fernando García Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0425-01942 – Residential Addition/Alteration 2750 W Placita Sombra Chula Tucson, AZ 85745 TRANSMITTAL DATE: May 14, 2025 This site is located in the R-3 zone (UDC 4.7.12). Per UDC Table 4.8-2, a single-family residence is a permitted use in this zone. 1. (Comment) This parcel is part of both the Hillside Development Zone (HDZ) overlay (UDC 5.2) and Scenic Corridor Zone (SDZ) overlay (UDC 5.3). This is also indicated on the original subdivision plat. Please correct general note 8 to state that this development complies with the requirements of both overlays. 2. (Comment) Parcels in a Hillside Development Zone (HDZ) are required to submit a Hillside Development Zone Plan in accordance with UDC 5.2.9 and UDC Technical Standards Manual (TSM) 9-01.0.0. 3. (Comment) Grading plans must be submitted as development package (DP) application types. Please submit a separate development package (DP) that includes the grading plan, retaining wall, Hillside Development Zone Plan, Native Plant Preservation Plan, and addresses any requirements related to the Scenic Corridor Zone overlay. Approval of this building permit will not be granted until the DP is first approved. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Corrected plans, with a comment response letter that indicates the response to each comment. Separate development package per comment #3. If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov. |
||
| 05/22/2025 | Fire New Construction - Standard | REVIEW COMPLETED | |||
| 04/14/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |