Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL POOL v.1
Permit Number - TC-RES-0425-01842
Review Name: RESIDENTIAL POOL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/24/2025 | Site Engineering | NOT REQUIRED | |||
| 05/02/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/29/2025 | Historic | REQUIRES RESUBMIT | Staff has opened and completed initial review under the TC-RES-0425-01842 and opened the Historic sub-record. Please submit all the same materials under the Historic sub-record in a single compressed pdf file to apply for a SD#. Review fees will be invoiced for payment. Attached is a link on how to get to the sub-record. https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf Contact Michael.Taku@tucsonaz.gov |
||
| 05/02/2025 | Residential Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0425-01842 PROJECT: RESIDENTIAL POOL ADDRESS/PARCEL: 520 E 4TH ST Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. COMMENTS: 1. Please remove the flagstone, existing planter, and hardscape around the existing firepit from the planset – it is unnecessary and makes reading the plans difficult. 2. Show all gate swings on the existing gates. 3. The elevated spool needs to be at a minimum of 2’ from the existing wall. 4. Combine the electrical and plumbing plan into one document. 5. How large is the natural gas heater? Please include that in the Plumbing Run calculation- for example 30’X2” for 400K BTU Heater 6. Include the material of the gas pipe run. More comments may be forth coming once corrections have been made. Please upload your revised plans to TDC-Online with a revision letter outlining what has been revised on the doc set. Resubmittals will not be accepted without the revision letter that answers all of the above comments. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov |
||
| 04/28/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0425-01842 502 E 4th St Tucson, AZ 85705 (HR-2 Zoning) New Residential Swimming Pool Residential Building - Building Plan Review - 1st Review TRANSMITTAL DATE: April 28, 2025 This site is located in an HR-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to use-specific standards 4.9.7.B.6, .9. and .10. COMMENTS: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. COMMENT: This site is located in the HR-2 zone (UDC 4.7.9). Historic review and approval are required. Site zoning cannot approve this permit until the historic review has been completed and approved. Please submit a special districts application as a sub-record of this permit. The submittal requirements and instructions can be found below. Please contact Michael Taku michael.taku@tucsonaz.gov for any questions. Zoning cannot approve this permit application until the historic review has been approved. 2. COMMENT: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Jeffrey W. Cassidy at jeffrey.cassidy@tucsonaz.gov. |
||
| 04/15/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |