Permit Review Detail
Review Status: Approved
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0425-01797
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/06/2025 | Residential Building - Standard | APPROVED | Install Safety Glazing if R308.4.2 is applicable, inspector will verify. R308.4.2 Glazing adjacent to doors. INSIGHTS Glazing in an individual fixed or operable panel adjacent to a door shall be considered to be a hazardous location where the bottom exposed edge of the glazing is less than 60 inches (1524 mm) above the floor or walking surface and it meets either of the following conditions:1. Where the glazing is within 24 inches (610 mm) of either side of the door in the plane of the door in a closed position.2. Where the glazing is on a wall less than 180 degrees (3.14 rad) from the plane of the door in a closed position and within 24 inches (610 mm) of the hinge side of an in-swinging door. |
||
| 05/12/2025 | Site Zoning - Standard | APPROVED | |||
| 05/09/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 05/12/2025 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 04/10/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |