Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0425-01750
Parcel: 130112400

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0425-01750
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/04/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT ACTIVITY NO. TC-RES-0425-01750
ADDRESS/PARCEL: (2141 S HEMLOCK SV TUCSON, AZ 85745)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter.

1. Please show individual branches to all attached appliances. Include pipe size, type (Black Iron, Poly) and length. G2413.4.1.
2. Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) Polyethylene Plastic Pipe. Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1.
3. Please resubmit
04/03/2025 PDSD Application Completeness Express REVIEW COMPLETED