| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/31/2024 | Site Engineering | NOT REQUIRED | |||
| 05/31/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/15/2024 | Residential Building | REQUIRES RESUBMIT | 1. Show the (carport roof) structure with one-hour fire-resistive wall construction parallel with the adjoining (neighboring) property line in compliance with IBC Table 721.1(2) or provide a clear 3’ fire separation distance between the property line and the structure. This construction or separation is required from ground to roof and from end to end of the roof which resists fire spread across the property line. 2. A roof projection may not extend closer than 24” to the adjoining (neighboring) property line. |
||
| 05/28/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0424-02583 5509 East 4th Street – R-1 Detached carport (1st Review) TRANSMITTAL DATE: May 28, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Indicate the scale of the site plan (i.e., 1” = 10’). 2. The lot coverage calculation is incorrect and should also include the existing driveway (UDC 6.4.3.B.3.b). Lot coverage shall not exceed 70% of the total lot area (UDC Table 6.3-2.A). 3. The distance between the centerline of 4th Street to the curb location, as well as the distance between the curb location and the street property line, are incorrect. Per page 14 of Paving Plan I-835, the dimension between the centerline of 4th Street and the street property line is 30 feet. Additionally, the distance between the centerline of 4th Street to the face of curb is 13’-6”, and the distance between the face of curb and the street property line is 16’-6”: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-835. Provide the above dimensions on the site plan to ensure the minimum required street perimeter yard setback is satisfied. Per UDC 6.4.5.C.1.a, the minimum required front street perimeter yard setback is twenty feet. However, shade structures or carports may project up to ten feet into the required setback (UDC 6.4.5.D.3). If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 05/02/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |