Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0424-02475
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/02/2024 | Fire New Construction | NOT REQUIRED | |||
| 05/28/2024 | Site Engineering | NOT REQUIRED | |||
| 05/15/2024 | Site Landscape | NOT REQUIRED | |||
| 05/28/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/09/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0424-02475 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with submitting the updated construction plan set. The construction plan set should show all proposed additions, repairs and alterations to the building and parcel. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: Show the location of all utility lines from property line to building(s) along with required alterations, R106.1.1. FLOOR PLAN: Provide a floor plan showing each proposed room with labeled function and dimensions. Show door locations and window sizes with type identified as XO or SH. An altered bedroom requires code compliance for egress, R310. SECTIONS - DETAILS: 1. Provide a complete cross-section detail showing proposed material sizes and ratings, R106.1. 2. Provide a structure section showing existing and proposed features including a foundation, framing, sills, anchoring, sheathing and insulation, R106.1. 3. Provide a complete cross-section detail showing type and size of framing, exterior wood siding, insulation, interior sheathing, and pressure treated sill anchored with ½” x 10” bolts. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. 4. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. ELECTRICAL PLANS: 1. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity, R314.3. 2. Notate interior (dwelling) 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 05/24/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Fernando Garcia Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0424-02475 – Residential Addition/Alteration 2108 N Calle de la Ciénega Building Plan Review (1st Review) TRANSMITTAL DATE: May 24, 2024 This site is located in the O-3 zone (UDC 4.7.15). 1. (Comment) The submitted site plan does not meet requirements for site plans from the City of Tucson. Please provide a depiction of the entire parcel, property lines, all structures, fence, and/or walls (existing and planned), setbacks to adjoining property lines, and all corresponding measurements and dimensions. Please also include lot coverage and density calculations. 2. (Comment) For an example of information required for a site plan by the City of Tucson, please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Updated site plan per requirements indicated in Comment #2 above. If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov or (520) 837-4894. |
||
| 04/25/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |