Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0424-02475
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/26/2024 | Site Zoning | APPROVED | |||
| 08/26/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/30/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0424-02475 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with submitting the updated construction plan set. Place a page number on each sheet of the construction plan set. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Show the location of the electrical service panel on the Plot Plan, R106.1.1. FLOOR PLAN: 1. The front bedroom requires a code compliant egress opening to the exterior, R310. Show an appropriate window size. The 3x4 XO is undersized with an opening width less than 20”. SECTIONS - DETAILS: 1. Provide a structure section showing proposed features including a reinforced foundation, framing size, pressure treated sills, ½”x10” anchoring, roof sheathing and ceiling insulation, R106.1. Update Figure 21C. 2. Framed exterior walls of enclosed roof structures require continuous concrete footings of minimum 12” width and 12” below the undisturbed ground surface with a #4 rebar, R403.1. Update Figure 26. 3. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. This may include a concrete stem for raising the sill plate. A 4” slab usually includes compacted fill for raising the floor level. Update Figure 26. 4. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Update Figure 21C. MECHANICAL PLANS: 1. The HVAC pages are not required if not altered, R106.1. ELECTRICAL PLANS: 1. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity, R314.3. 2. Notate interior (new or altered) 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. Add the requirement to circuit #21. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 07/29/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |