Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0424-02461
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/24/2024 | Fire New Construction | NOT REQUIRED | |||
| 05/09/2024 | Residential Building | NOT REQUIRED | |||
| 05/21/2024 | Site Engineering | NOT REQUIRED | |||
| 05/15/2024 | Site Landscape | NOT REQUIRED | |||
| 05/23/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/23/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Georgia Pennington Planner PROJECT: TC-RES-0424-02461 2895 E ALLEN RD. – R-1 Attached Shade Sails (2nd Review) TRANSMITTAL DATE: May 23, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. 1. Provide a complete plot plan that includes all the required elements. Residential plot plan requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. a. Clarify what scale the plot plan is drawn at. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” =20’, etc. b. Provided the legal description, Allen Road Subdivision Lot 1, on the plot plan. c. Provide a lot coverage calculation on the plot plan. d. Provide the zoning of this property and all surrounding properties on the plot plan. e. The property shape is not correct. Per the Allen Road Subdivision found at: https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=49017, there is a 30’ spandrel at the southeast corner of this property. Show the spandrel on the plan. 2. Based on the approved permit, T97CM00557, for this single family residence (SFR) the house should have be located 20’-0” from the south street property line, this plan shows the SFR located 30’-0’ from the south property line. Also this plans shows the east side of the SFR 4.08’ from the east property line when the approved plans show it at 9’-0”. A survey prepared by a register surveyor may be required to verify that all proposed are located within the property boundaries. 3. Per UDC Article 6.4.5.C.1 the required street perimeter yard setback from the proposed columns supporting the shade sail is 20’-0”, proposed setback is 2’-0”. Per UDC Article 6.4.5.B.2 A vertical structural member(s) (i.e., post, column, dormer wall) supporting a roof extension from the principal structure is considered a wall for applying perimeter yard requirements. 4. Per UDC Table 6.3-2.A the required perimeter yard setback from the proposed column supporting the shade sail to west property line is the greater of 6’-0” or 2/3 the height of the proposed column. Based on a height of 7’-0” the required perimeter yard setback from the column to the west property line is 6’-0”, proposed setback is 2.08’. To reduce the required perimeter yard setbacks a Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/24/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |